Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2016, 05:33 PM
  • 05 1256A_05 1256_6172016_103544.mp4

Date
06/17/2016
W/O
0574349
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00518
PipeID
P06465
Time
10:33 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7154
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
20160616AM_SO_HAWTHORNE_WARFIELD_AV_EXT_TR_SECT_4
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
05 1256A
Downstream MH
05 1256
Dir. of Survey
Downstream
Length Surveyed
207.2 ft.
Total Length
207.2 ft.
Structural Index
3
Structural Quick
5543
Structural Rating
61
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
61
Pipe schematic from manhole 05 1256A to 05 1256
MH: 05 1256AMH: 05 1256downstream0 ft. MGO - General Observation - OPEN CONN. INSIDE THE MH. @ 09 O'CLOCK0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 10:34 AM0 ft. MWM - Water Mark, 40 %of cross sectional area3.3 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES8.5 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES13.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES23.7 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES23.7 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES38.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES38.8 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES43.7 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES53.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.2 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES64.2 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES73.9 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES114.6 ft. B - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES114.6 ft. MGP - General Photograph - BROKEN PIPE124.7 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES144.9 ft. B - Broken, from 11 to 04 o'clock, within 8 inches of joint: YES159.8 ft. B - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES175.3 ft. B - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES195.3 ft. B - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES205.3 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH205.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish205.7 ft. MGO - General Observation - CAPPED CONN. INSIDE THE MH. @ 03 O'CLOCK205.7 ft. MGO - General Observation - CAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK207.2 ft. AMH - Downstream Manhole, Survey Ends - 11:01 AM

Observation photos (11)

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    38.8 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    43.7 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES

    64.2 ft. - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    73.9 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

    114.6 ft. - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

  • General Photograph - BROKEN PIPE

    114.6 ft. - General Photograph - BROKEN PIPE

  • Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    124.7 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Broken, from 11 to 04 o'clock, within 8 inches of joint: YES

    144.9 ft. - Broken, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

    159.8 ft. - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

    175.3 ft. - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

    195.3 ft. - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (29)

DistanceCodeObservation
23.7CC
114.6B
73.9FM
207.2AMH11:01 AM
195.3B
8.5CL
0MGOOPEN CONN. INSIDE THE MH. @ 09 O'CLOCK
13.4CM
205.3MGOSLIGHT GREASE THROUGHOUT THE REACH
205.7MGOCAPPED CONN. INSIDE THE MH. @ 03 O'CLOCK
205.3CM
0MWL
144.9B
38.8FL
0MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
175.3B
43.7FM
3.3CM
53.6CM
0AMH10:34 AM
205.7MGOCAPPED CONN. INSIDE THE MH. @ 09 O'CLOCK
124.7FM
38.8FC
0MWM
64.2FL
64.2FC
114.6MGPBROKEN PIPE
23.7CL
159.8B

Properties (4)

custom_field_three
BROKEN PIPE
custom_field_two
1
customer
LACSD
datetime