05 1270_05 1269_6142016_090459.mp4
35.2 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES
64.6 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED, STUFFED WITH DEBRIS
80.7 ft. - General Photograph - BLOCKAGE INSIDE THE PROTRUDING CONN.
80.7 ft. - Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - UNKNOWN, 100% BLOCKAGE
180 ft. - General Observation - CHIPPING
212.4 ft. - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES
225.7 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN, 90% BLOCKED
229.7 ft. - General Photograph - 95% ROOT BLOCKAGE INSIDE THE CONN.
229.7 ft. - Tap Factory Made Intruding, at 02 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - OPEN, 95% BLOCKAGE
268.4 ft. - General Photograph - CHIPPING
304.8 ft. - Joint Separated Medium
| Distance | Code | Observation |
|---|---|---|
| 80.7 | MGP | BLOCKAGE INSIDE THE PROTRUDING CONN. |
| 63.1 | CM | — |
| 59.1 | CM | — |
| 340.9 | CM | — |
| 341.1 | MGO | ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK |
| 55.2 | CM | — |
| 0 | AMH | 9:03 AM |
| 0 | MGO | ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK |
| 0 | MGO | CAPPED CONN. INSIDE THE MH. @ 03 O'CLOCK |
| 261.8 | TFC | — |
| 229.7 | MGP | 95% ROOT BLOCKAGE INSIDE THE CONN. |
| 174 | TB | OPEN |
| 14.4 | CL | — |
| 67.2 | CM | — |
| 340.9 | MGO | SLIGHT GREASE THROUGHOUT THE REACH |
| 290 | TFD | CAPPED, CRACKED |
| 268.4 | MGP | CHIPPING |
| 0 | MWM | — |
| 229.7 | TFI | OPEN, 95% BLOCKAGE |
| 31.1 | CM | — |
| 64.6 | TFD | CRACKED, STUFFED WITH DEBRIS |
| 192.1 | RTJ | — |
| 180 | MGO | CHIPPING |
| 212.4 | FM | — |
| 304.8 | JSM | — |
| 35.2 | B | — |
| 0 | MWL | — |
| 80.7 | TFI | UNKNOWN, 100% BLOCKAGE |
| 225.7 | TFD | UNKNOWN, 90% BLOCKED |
| 153.3 | TFC | — |
| 23.1 | CM | — |
| 18.8 | CM | — |
| 342.5 | AMH | 9:47 AM |