Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 18, 2016, 04:04 PM
Date
05/18/2016
W/O
0568717
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00130
PipeID
P09698
Time
9:04 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7124
Sewer Name
C JOINT OUTFALL C - UNIT 5C
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
10
Purpose
Routine Assessment
Project
20160517AM_JOINT_OUTFALL_C_UNIT_5C
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
C 0174
Downstream MH
C 0173
Dir. of Survey
Downstream
Length Surveyed
257 ft.
Total Length
257 ft.
Structural Index
4
Structural Quick
5731
Structural Rating
40
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
42
Pipe schematic from manhole C 0174 to C 0173
MH: C 0174MH: C 0173downstream0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:50 PM0 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start3.1 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO3.8 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES25.6 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO30.9 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO88.3 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO98.2 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO140.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"201 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES249.2 ft. SRV - Surface Reinforcement Visible, from 02 to 04 o'clock, within 8 inches of joint: YES254.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish254.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish255.1 ft. MGO - General Observation - ROACHES INSIDE THE MH.255.1 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK255.1 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK257 ft. AMH - Downstream Manhole, Survey Ends - 1:10 PM

Observation photos (1)

  • Upstream Manhole, Survey Begins - 12:50 PM

    0 ft. - Upstream Manhole, Survey Begins - 12:50 PM

Observations (22)

DistanceCodeObservation
0MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
257AMH1:10 PM
3.1SRV
0MWL
201DAE
25.6SRV
2SAV
3.8SRV
255.1MGOROACHES INSIDE THE MH.
255.1MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
2SSS
30.9SRV
0MWM
140.7TFA
249.2SRV
0AMH12:50 PM
254.4SAV
88.3SRV
0MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
255.1MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
254.4SSS
98.2SRV

Properties (5)

additional_info
COULD NOT TAKE PICS, COMPUTER PROBLEMS
custom_field_three
REBAR
custom_field_two
2
customer
LACSD
datetime
2016-05-18T09:04:17-07:00