Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 9, 2016, 11:05 AM
  • E 0211_E 0094_592016_040912.mp4

Date
05/09/2016
W/O
0563852
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00484
PipeID
P05979
Time
4:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0124
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
LYNWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20160509MDM_MANCHESTER_VERMONT_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
E 0211
Downstream MH
E 0094
Dir. of Survey
Downstream
Length Surveyed
378.9 ft.
Total Length
378.9 ft.
Structural Index
2
Structural Quick
4533
Structural Rating
69
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
69
Pipe schematic from manhole E 0211 to E 0094
MH: E 0211MH: E 0094downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active OUTGOING LINE0 ft. AMH - Upstream Manhole, Survey Begins - 3:55AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 0 %of cross sectional area - DRY LINE5.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT6 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE9.4 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SLIGHT13.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT13.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SLIGHT17.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT21.2 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE21.2 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT25.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT29.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE33.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT37.5 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT37.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H41.7 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT41.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE45.4 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS45.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS45.4 ft. FL - Fracture Longitudinal, at 08 TO4o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS45.4 ft. MGO - General Observation - 15" VCP45.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS70.1 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE78.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE81.8 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - MODERATE118.1 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE126 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE142.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT150.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE174.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - MODERATE315.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT378.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active INCOMING LINE378.5 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Finish - 30% HAIRLINE378.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 70% HAIRLINE378.5 ft. MGP - General Photograph - Conn. @ Mh, 3 O' Clock. Active OUTGOING LINE378.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 90% SLIGHT378.5 ft. FL - Fracture Longitudinal, at 08 TO 4o'clock, within 8 inches of joint: YES, Finish - 40% SLIGHT378.9 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (13)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    17.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    25.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

    33.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    41.7 ft. - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • General Observation - 15" VCP

    45.4 ft. - General Observation - 15" VCP

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    70.1 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    78.2 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - MODERATE

    81.8 ft. - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    118.1 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    126 ft. - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    142.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

    150.3 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - MODERATE

  • Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - MODERATE

    174.6 ft. - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - MODERATE

Observations (40)

DistanceCodeObservation
378.5MGOConn. @ Mh, 9 O' Clock. Active INCOMING LINE
41.7FCSLIGHT
45.4FLHAIRLINE AT JOINTS
0MGOConn. @ Mh, 3 O' Clock. Active OUTGOING LINE
5.6FCSLIGHT
13.4FCSLIGHT
78.2FCMODERATE
378.5FL30% HAIRLINE
150.3FCMODERATE
378.9AMH5:15AM
33.5FMSLIGHT
174.6FCMODERATE
142.8FMSLIGHT
9.4FCSLIGHT
13.4FLSLIGHT
21.2FCHAIRLINE
378.5FC70% HAIRLINE
0AMH3:55AM
378.5MGPConn. @ Mh, 3 O' Clock. Active OUTGOING LINE
37.5FCSLIGHT
315.9FMSLIGHT
29.3FCHAIRLINE
118.1FCMODERATE
41.7FCMODERATE
21.2FCSLIGHT
81.8FCMODERATE
45.4FCHAIRLINE AT JOINTS
45.4FLSLIGHT AT JOINTS
0MWM
6FCHAIRLINE
70.1FCMODERATE
25.4FMSLIGHT
45.4MGO15" VCP
378.5FC90% SLIGHT
0MWLDRY LINE
45.4FCSLIGHT AT JOINTS
378.5FL40% SLIGHT
37.5FCH
17.6FMSLIGHT
126FCMODERATE

Properties (4)

custom_field_three
MODERATE FRACTRES-MULTIPLE SLIGHT
custom_field_two
2
customer
LACSD
datetime
2016-05-09T04:05:38-07:00