Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2016, 10:43 AM
  • 05 0759_05 0758_542016_041253.mp4

Date
05/04/2016
W/O
0563852
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00484
PipeID
P05986
Time
3:43 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0121
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20160503MDM_MANCHESTER_VERMONT_RELIEF_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
05 0758
Downstream MH
05 0759
Dir. of Survey
Upstream
Length Surveyed
421.7 ft.
Total Length
421.7 ft.
Structural Index
2
Structural Quick
352B
Structural Rating
43
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
45
Pipe schematic from manhole 05 0758 to 05 0759
MH: 05 0758MH: 05 0759upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:05AM0.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 70% SLIGHT0.7 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 30% SLIGHT0.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 60% HAIRLINE0.7 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 20% HAIRLINE0.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Finish145.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start367.4 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS367.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS367.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS367.4 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS371.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H375.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT375.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE379.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE380 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT383.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT387.1 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SLIGHT391.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT395.2 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - SLIGHT399.5 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT407.6 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT407.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - HAIRLINE411.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - MODERATE411.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT415.9 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT-CHIPPED421.7 ft. MWM - Water Mark, 40 %of cross sectional area421.7 ft. MWL - Water Level, 10 %of cross sectional area421.7 ft. AMH - Downstream Manhole, Survey Begins - 4:10AM

Observation photos (3)

  • Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT-CHIPPED

    5.8 ft. - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT-CHIPPED

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - MODERATE

    10.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - MODERATE

  • Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock,  , within 8 inches of joint: YES, Start

    276.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES, Start

Observations (29)

DistanceCodeObservation
54.3FLHAIRLINE AT JOINTS
14.1FCSLIGHT
34.6FCSLIGHT
276.4DAGS
30.3FLSLIGHT
26.5FCSLIGHT
421FC70% SLIGHT
421FL30% SLIGHT
41.7FCSLIGHT
46.3FCSLIGHT
421FC60% HAIRLINE
421FL20% HAIRLINE
9.9FCSLIGHT
38.4FCSLIGHT
0MWM
46.3FCHAIRLINE
14.1FCHAIRLINE
5.8FCSLIGHT-CHIPPED
42.6FLHAIRLINE
22.2FCSLIGHT
421.7AMH5:05AM
54.3FCSLIGHT AT JOINTS
50.3FCH
54.3FCHAIRLINE AT JOINTS
10.4FLMODERATE
54.3FLSLIGHT AT JOINTS
421DAGS
0MWL
0AMH4:10AM

Properties (4)

custom_field_three
SLIGHT FRACTURES 1 MODERATE
custom_field_two
2
customer
LACSD
datetime
2016-05-04T03:43:56-07:00