Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2016, 07:38 AM
  • 08 0038_08 0037_532016_023627.mp4

Date
05/03/2016
W/O
0563840
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00040
Time
12:38 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0119
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
20160503MDM_MAIN_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
08 0038
Downstream MH
08 0037
Dir. of Survey
Downstream
Length Surveyed
169.6 ft.
Total Length
169.6 ft.
Structural Index
3
Structural Quick
3625
Structural Rating
28
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole 08 0038 to 08 0037
MH: 08 0038MH: 08 0037downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWL - Water Level, 10 %of cross sectional area0.1 ft. MWM - Water Mark, 20 %of cross sectional area2.5 ft. MGO - General Observation - 21" VCP6.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped11.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - HAIRLINE26.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H29.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H45.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H55.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped67.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H82 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H107.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open113.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H137.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT149.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - SLIGHT156 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped158.8 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES - H164.3 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H169.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active169.6 ft. AMH - Downstream Manhole, Survey Ends - 2:35AM

Observation photos (2)

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped

    6.5 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - SLIGHT

    149.7 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (22)

DistanceCodeObservation
29.7FLH
137.6FCSLIGHT
0MGOConn. @ Mh, 9 O' Clock. Active
11.6FLHAIRLINE
107.6TFOpen
67.3FCH
6.5TFCCapped
0AMH2:15AM
45.2FLH
2.5MGO21" VCP
169.6AMH2:35AM
0.1MWM
164.3FCH
0MWL
158.8FCH
113.2FLH
149.7FLSLIGHT
156TFCCapped
26.8FLH
169.2MGOConn. @ Mh, 9 O' Clock. Active
55.5TFCCapped
82FCH

Properties (4)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2016-05-03T00:38:56-07:00