- Date
- 04/30/2016
- W/O
- 0563839
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00016
- PipeID
- P00007
- Time
- 1:55 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6697
- Sewer Name
- 08 MAIN STREET TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160430MDM_MAIN_STREET_TRUNK
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- 08 0007
- Downstream MH
- 08 0006
- Dir. of Survey
- Downstream
- Length Surveyed
- 15 ft.
- Total Length
- 15 ft.
- Structural Index
- 5
- Structural Quick
- 5242
- Structural Rating
- 18
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 23
Pipe schematic from manhole 08 0007 to 08 0006 Observation photos (5)

2 ft. - Surface Reinforcement Visible, from 11 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

5 ft. - General Observation - MAG COAT 70% START

5 ft. - General Observation - MISSING BTILES 10% START UNDER MAG COAT

5 ft. - General Photograph

13.8 ft. - General Observation - MISSING TILES 90%