2 ft. - General Observation - MISSING TILES 20% START
2 ft. - General Observation - MAG COAT 50% START 9:00 TO 3:00
55.9 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES
57.7 ft. - General Observation - NEW MISSING TILES 2:00
63.3 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
72.1 ft. - Surface Aggregate Projecting, from 12 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
75.7 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
84.4 ft. - General Observation - MISSING TILES 100% 9:00 TO 3:00
101.4 ft. - General Observation - MISSING TILES 100%
148 ft. - General Observation - MISSING TILES 80%
149.3 ft. - Surface Aggregate Missing, from 01 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG
168.2 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
173.9 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
186.4 ft. - General Observation - MISSING TILES 100%START
190.8 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR
201 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - CIRCUM
215.7 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM
218 ft. - General Observation - MISSING TILES 90% START 10: TO 2:00
229.7 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: YES - CIRCUM
232.1 ft. - Surface Reinforcement Visible, at 10 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
234.7 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO, Start - CIRCUM
251.5 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM
252.2 ft. - Surface Reinforcement Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - CIRCUM
257.2 ft. - Surface Reinforcement Visible, from 01 to 03 o'clock, within 8 inches of joint: NO
| Distance | Code | Observation |
|---|---|---|
| 264.7 | AMH | 3:40AM |
| 201 | SRV | CIRCUM |
| 84.4 | MGO | MISSING TILES 100% 9:00 TO 3:00 |
| 232.1 | SRV | CIRCUM REBAR |
| 218 | MGO | MISSING TILES 90% START 10: TO 2:00 |
| 239 | SRV | — |
| 234.7 | SRV | CIRCUM |
| 148 | MGO | MISSING TILES 80% |
| 252.2 | SRV | CIRCUM |
| 229.7 | SRV | CIRCUM |
| 0 | MWL | — |
| 195.1 | SRV | — |
| 63.3 | DAGS | — |
| 149.3 | SAM | SEVERE AGG |
| 72.1 | SAP | SEVERE AGG |
| 215.7 | SRV | CIRCUM |
| 101.4 | MGO | MISSING TILES 100% |
| 251.5 | SRV | CIRCUM |
| 190.8 | SRV | CIRCUM REBAR |
| 264.2 | DAGS | — |
| 264.2 | MGO | MISSING TILES 90% FINISH |
| 264.2 | SAV | SEVERE AGG |
| 257.2 | SRV | — |
| 57.7 | MGO | NEW MISSING TILES 2:00 |
| 2 | MGO | MISSING TILES 20% START |
| 2 | MGO | MAG COAT 50% START 9:00 TO 3:00 |
| 75.7 | SRV | CIRCUM REBAR |
| 168.2 | SRV | CIRCUM REBAR |
| 264.2 | SRV | CIRCUM |
| 173.9 | SRV | CIRCUM REBAR |
| 264.2 | MGO | MAG COAT 50% FINISH |
| 0 | AMH | 3:00AM |
| 186.4 | MGO | MISSING TILES 100%START |
| 203.2 | MGO | 100% MISSING TILES FINISH |
| 0 | MWM | — |
| 84.4 | DSZ | FALLEN TILES |
| 168.2 | MGO | MISSING TILES 80% |
| 55.9 | SAV | SEVERE AGG AREAS OF MISSING TILES |