- Date
- 04/07/2016
- W/O
- 0552270
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00431
- PipeID
- P21393
- Time
- 1:24 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G6681
- Sewer Name
- 05 DISTRICT #5 MAIN TRUNK
- City
- TORANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- 20160406MDM_DISTRICT_5_MAIN_TRUNK
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 48 in.
- Upstream MH
- 05 0040
- Downstream MH
- A 0983
- Dir. of Survey
- Downstream
- Length Surveyed
- 190.1 ft.
- Total Length
- 190.1 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 0
- Overall Quick
- —
- Overall Rating
- 0
Pipe schematic from manhole 05 0040 to A 0983 Observation photos (5)

8 ft. - General Observation - 48" RCP-CTL FR POLY

15.7 ft. - General Observation - WHITE BUILDUP ON PIPE

15.7 ft. - General Photograph

166.1 ft. - General Photograph

190.1 ft. - Downstream Manhole, Survey Ends - 5:15AM STOPLOG IN PLACE NO FLOW DOWNSTREAM