Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 5, 2016, 09:12 AM
Date
04/05/2016
W/O
0557603
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00488
PipeID
P06310
Time
2:12 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6677
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
21
Purpose
Routine Assessment
Project
20160405MDM_MONETA_EXTENSION_TRUNK_SECTION_1
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 1076
Downstream MH
05 1075
Dir. of Survey
Downstream
Length Surveyed
318.4 ft.
Total Length
318.4 ft.
Structural Index
2
Structural Quick
3123
Structural Rating
12
O&M Index
2
O&M Quick
412L
O&M Rating
132
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole 05 1076 to 05 1075
MH: 05 1076MH: 05 1075downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:45AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start11 ft. MGO - General Observation - 24" VCP50.4 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"118.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES151.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"166.1 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES207.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN229.7 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES241.4 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE253.4 ft. CC - Crack Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES289.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE308.1 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - HAIRLINE318.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish318.1 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES - INSIDE MH318.1 ft. MGO - General Observation - MH CONN STUB 9:00318.1 ft. MGO - General Observation - MH CONN ACTIVE 3:00318.4 ft. AMH - Downstream Manhole, Survey Ends - 3:10AM

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - 24" VCP

    11 ft. - General Observation - 24" VCP

Observations (20)

DistanceCodeObservation
151.1TFC
118.4CL
166.1CC
2DAGS
207.4TFOPEN
11MGO24" VCP
0MWM
50.4TFC
253.4CC
318.4AMH3:10AM
229.7CC
318.1DAGS
308.1FCHAIRLINE
318.1DAGSINSIDE MH
0AMH2:45AM
289.1FLHAIRLINE
318.1MGOMH CONN STUB 9:00
318.1MGOMH CONN ACTIVE 3:00
0MWL
241.4FCHAIRLINE

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-04-05T02:12:53-07:00