- Date
- 03/29/2016
- W/O
- 0557603
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00488
- PipeID
- P06330
- Time
- 3:50 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0102
- Sewer Name
- 05 MONETA EXTENSION TRUNK, SECTION 1
- City
- LAWNDALE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- 20160325MDM_MONETA_EXTENSION_TRUNK_SECTION_1
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 05 1096
- Downstream MH
- 05 1095
- Dir. of Survey
- Downstream
- Length Surveyed
- 320.6 ft.
- Total Length
- 320.6 ft.
- Structural Index
- 3
- Structural Quick
- 433C
- Structural Rating
- 114
- O&M Index
- 3
- O&M Quick
- 3100
- O&M Rating
- 3
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 117
Pipe schematic from manhole 05 1096 to 05 1095 Observation photos (3)

46 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 6" - 80% ROOTS

311 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT

317.7 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE