- Date
- 03/29/2016
- W/O
- 0557603
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00488
- PipeID
- P06333
- Time
- 12:45 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0101
- Sewer Name
- 05 MONETA EXTENSION TRUNK, SECTION 1
- City
- LAWNDALE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- 20160325MDM_MONETA_EXTENSION_TRUNK_SECTION_1
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 05 2504
- Downstream MH
- 05 1098
- Dir. of Survey
- Downstream
- Length Surveyed
- 311.4 ft.
- Total Length
- 311.4 ft.
- Structural Index
- 3
- Structural Quick
- 3A2A
- Structural Rating
- 58
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 62
Pipe schematic from manhole 05 2504 to 05 1098 Observation photos (3)

1 ft. - General Photograph - PAPER BUILDUP

45.1 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, - H

211.8 ft. - General Observation - 12" VCP