Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2016, 02:59 PM
  • 08 0053_08 0052_3232016_080954.mp4

Date
03/23/2016
W/O
0557605
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00016
PipeID
P00055
Time
7:59 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7081
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
20160322AM_MAIN_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
08 0053
Downstream MH
08 0052
Dir. of Survey
Downstream
Length Surveyed
325.2 ft.
Total Length
325.2 ft.
Structural Index
2
Structural Quick
3125
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 08 0053 to 08 0052
MH: 08 0053MH: 08 0052downstream0 ft. MGO - General Observation - ROACHES INSIDE THE MH.0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 8:10 AM27 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - UNKNOWN34.5 ft. CC - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES77.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"128.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"174.8 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES175.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"180.5 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES195.3 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES210.5 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES216.5 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES229.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"261.1 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES277.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN323.5 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH323.6 ft. MGO - General Observation - ROACHES INSIDE THE MH.323.6 ft. MGO - General Observation - CORRODING CHANNEL325.2 ft. AMH - Downstream Manhole, Survey Ends - 8:41 AM

Observation photos (1)

  • Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN

    277.2 ft. - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 4" - UNKNOWN

Observations (21)

DistanceCodeObservation
0MGOROACHES INSIDE THE MH.
277.2TFUNKNOWN
261.1CM
323.6MGOROACHES INSIDE THE MH.
0MWL
180.5CL
325.2AMH8:41 AM
77.7TFC
27TFUNKNOWN
195.3CL
323.5MGOSLIGHT GREASE THROUGHOUT THE REACH
174.8CL
0MWM
229.6TFC
216.5CL
210.5CL
128.6TFC
0AMH8:10 AM
175.7TFC
323.6MGOCORRODING CHANNEL
34.5CC

Properties (4)

custom_field_three
CRACKS
custom_field_two
3
customer
LACSD
datetime
2016-03-23T07:59:12-07:00