Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 17, 2016, 06:15 AM
Date
03/16/2016
W/O
0557681
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11472
Time
11:15 PM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6675
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Capital Improvement Program Assesment
Project
20160315MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0226
Downstream MH
J 0225
Dir. of Survey
Downstream
Length Surveyed
426.4 ft.
Total Length
426.4 ft.
Structural Index
3
Structural Quick
5848
Structural Rating
421
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
421
Pipe schematic from manhole J 0226 to J 0225
MH: J 0226MH: J 0225downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:25PM2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR2 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG6 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG REBAR10.4 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - CIRCUM13.1 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish13.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LAITANCE COAT PEELNG BLISTERING13.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG17.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG27.3 ft. SRV - Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR27.3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC28 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG34.4 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM SPORATIC34.4 ft. SRV - Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: YES, Finish - LONG REBAR56.7 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish58.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - LAITACE COAT PEELING BLISTERING89 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES93.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG101.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES108.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG118.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC131.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE307.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC426.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING BLISTERING LAITANCE COAT426.1 ft. MGO - General Observation - MH CONN STUB 9:00426.1 ft. MGO - General Observation - MH CONN STUB 3:00426.4 ft. AMH - Downstream Manhole, Survey Ends - 12:15AM

Observation photos (15)

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

    2 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LAITANCE COAT PEELNG BLISTERING

    13.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LAITANCE COAT PEELNG BLISTERING

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

    13.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

    17.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

  • Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

    27.3 ft. - Surface Reinforcement Visible, at 03 o'clock, within 8 inches of joint: YES, Start - LONG REBAR

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

    27.3 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR SPORATIC

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    28 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - LAITACE COAT PEELING BLISTERING

    58.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - LAITACE COAT PEELING BLISTERING

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    89 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    93.3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

    101.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    118.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE

    131.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES - SEVERE

Observations (30)

DistanceCodeObservation
0MWL
426.1SSSPEELING BLISTERING LAITANCE COAT
56.7SAM
34.4SRVCIRCUM SPORATIC
34.4SRVLONG REBAR
17.5SAVSEVERE AGG
27.3SRVLONG REBAR
0MWM
89SSS
58.5SSSLAITACE COAT PEELING BLISTERING
2SRCCIRCUM REBAR
101.1SSS
426.4AMH12:15AM
13.1SAM
2SRCLONG REBAR
13.1SSSLAITANCE COAT PEELNG BLISTERING
426.1MGOMH CONN STUB 9:00
13.1SAVSEVERE AGG
28SAMSEVERE AGG
131.6SAVSEVERE
6SRCLONG REBAR
0AMH11:25PM
27.3SRVCIRCUM REBAR SPORATIC
93.3SAVSEVERE AGG
2SAMSEVERE AGG
108.8SAVSEVERE AGG
118.9SAVSEVERE AGG SPORATIC
426.1MGOMH CONN STUB 3:00