2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING LAITANCE COAT
17.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES
27.4 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO - BLISTERING LAITANCE COAT
34.1 ft. - General Observation - POSSIBLE STUB CONN
75.4 ft. - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT
161.8 ft. - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: YES
163.5 ft. - Surface Aggregate Visible, from 08 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
346.8 ft. - Downstream Manhole, Survey Ends MH# J 231 ABANDONED - 11:30PM-MH# J 231 ABANDONED
| Distance | Code | Observation |
|---|---|---|
| 346.4 | SSS | PEELING BLISTERING LAITANCE COAT |
| 0 | AMH | 10:55AM |
| 34.1 | MGO | POSSIBLE STUB CONN |
| 0 | MGO | MH CONN 9:00 STUB |
| 2 | SSS | PEELING BLISTERING LAITANCE COAT |
| 17.6 | SSS | — |
| 0 | MWM | — |
| 0 | MWL | — |
| 346.8 | AMH | 11:30PM-MH# J 231 ABANDONED |
| 161.8 | SSS | — |
| 75.4 | SSS | PEELING LAITANCE COAT |
| 27.4 | SSS | BLISTERING LAITANCE COAT |
| 0 | MGO | MH CONN ACTIVE 2:00 |
| 163.5 | SAV | SEVERE AGG SPORATIC |