Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2016, 07:28 AM
Date
03/15/2016
W/O
0557681
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00057
PipeID
P11481
Time
12:28 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6672
Sewer Name
J JOINT OUTFALL J - UNIT 1E
City
PALO VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47
Purpose
Capital Improvement Program Assesment
Project
20160315MDM_JOINT_OUTFALL_J_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
J 0235
Downstream MH
J 0234
Dir. of Survey
Downstream
Length Surveyed
353.6 ft.
Total Length
353.6 ft.
Structural Index
2
Structural Quick
322N
Structural Rating
154
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
154
Pipe schematic from manhole J 0235 to J 0234
MH: J 0235MH: J 0234downstream0 ft. MGO - General Observation - MH CONN STUB 3:000 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM0 ft. MGO - General Observation - MH CONN STUB 9:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT UNDER MAG COAT5 ft. MGO - General Observation - MAG COAT 80% 8:00 TO 4:00 START25 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT25 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG AT JOINT42.4 ft. SSS - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO104.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - POSSIBLE STUB112.7 ft. SSS - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES296.5 ft. SSS - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT323.8 ft. SAV - Surface Aggregate Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC353.3 ft. MGO - General Observation - MAG COAT 80% FINISH353.3 ft. MGO - General Observation - MH CONN STUB 9:00353.3 ft. MGO - General Observation - MH CONN STUB 3:00353.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING BLISTERING LAITANCE COAT353.6 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observation photos (9)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT UNDER MAG COAT

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING LAITANCE COAT UNDER MAG COAT

  • General Observation - MAG COAT 80% 8:00 TO 4:00 START

    5 ft. - General Observation - MAG COAT 80% 8:00 TO 4:00 START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT

    25 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT

  • Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG AT JOINT

    25 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG AT JOINT

  • Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO

    42.4 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: NO

  • Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - POSSIBLE STUB

    104.1 ft. - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - POSSIBLE STUB

  • Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES

    112.7 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT

    296.5 ft. - Surface Spalling, from 08 to 12 o'clock, within 8 inches of joint: YES - PEELING LAITANCE COAT

  • Surface Aggregate Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

    323.8 ft. - Surface Aggregate Visible, from 08 to 10 o'clock, within 8 inches of joint: YES - SEVERE AGG SPORATIC

Observations (17)

DistanceCodeObservation
353.3MGOMAG COAT 80% FINISH
104.1TFCPOSSIBLE STUB
353.3MGOMH CONN STUB 9:00
25SSSPEELING LAITANCE COAT
0MGOMH CONN STUB 3:00
0AMH1:45AM
2SSSBLISTERING PEELING LAITANCE COAT UNDER MAG COAT
323.8SAVSEVERE AGG SPORATIC
353.6AMH2:20AM
296.5SSSPEELING LAITANCE COAT
5MGOMAG COAT 80% 8:00 TO 4:00 START
353.3MGOMH CONN STUB 3:00
353.3SSSPEELING BLISTERING LAITANCE COAT
0MGOMH CONN STUB 9:00
112.7SSS
42.4SSS
25SAVSEVERE AGG AT JOINT

Properties (4)

custom_field_three
SEVERE AGG SPORATIC
custom_field_two
3
customer
LACSD
datetime
2016-03-15T00:28:46-07:00