Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 23, 2016, 08:44 AM
  • J 0059_J 0058_2232016_020059.mp4

Date
02/23/2016
W/O
0547047
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00062
PipeID
P11636
Time
12:44 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0063
Sewer Name
J JOINT OUTFALL J - UNIT 2C
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Capital Improvement Program Assesment
Project
20160223MDM_JOINT_OUTFALL_J_UNIT_2C
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Upstream MH
J 0059
Downstream MH
J 0058
Dir. of Survey
Downstream
Length Surveyed
692.8 ft.
Total Length
692.8 ft.
Structural Index
4
Structural Quick
5542
Structural Rating
41
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
41
Pipe schematic from manhole J 0059 to J 0058
MH: J 0059MH: J 0058downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:35AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 70% START 8:00 TO 4:008.7 ft. SRV - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUN REBAR20.6 ft. SRV - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Finish38 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM135.8 ft. MGO - General Observation - MAG COAT 25% START143.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish143.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG144.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING CONCRETE154.2 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR155.4 ft. SAV - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR156.6 ft. MGO - General Observation - MAG COAT 50% START178.4 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR212.5 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR266 ft. SAM - Surface Aggregate Missing, from 08 to 12 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG346.1 ft. SAM - Surface Aggregate Missing, from 08 to 12 o'clock, within 8 inches of joint: NO, Finish579 ft. MGO - General Observation - MAG COAT 70% START692.4 ft. MGO - General Observation - MAG COAT 70% FINISH692.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG692.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish692.8 ft. AMH - Downstream Manhole, Survey Ends - 2:40AM

Observation photos (12)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUN REBAR

    8.7 ft. - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES, Start - CIRCUN REBAR

  • General Observation - MAG COAT 25% START

    135.8 ft. - General Observation - MAG COAT 25% START

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    143.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING CONCRETE

    144.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING CONCRETE

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    154.2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    155.4 ft. - Surface Aggregate Visible, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • General Observation - MAG COAT 50% START

    156.6 ft. - General Observation - MAG COAT 50% START

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

    178.4 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    212.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • Surface Aggregate Missing, from 08 to 12 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

    266 ft. - Surface Aggregate Missing, from 08 to 12 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

  • General Observation - MAG COAT 70% START

    579 ft. - General Observation - MAG COAT 70% START

Observations (24)

DistanceCodeObservation
266SAMSEVERE AGG
692.4MGOMAG COAT 70% FINISH
212.5SRVLONG CIRCUM REBAR
346.1SAM
20.6SRV
692.8AMH2:40AM
156.6MGOMAG COAT 50% START
143.6SAM
2SAMSEVERE AGG
38SRVCIRCUM
8.7SRVCIRCUN REBAR
178.4SRVLONG REBAR
155.4SAVCIRCUM REBAR
0AMH1:35AM
0MWL
692.4SAVSEVERE AGG
144.2SSSPEELING BLISTERING CONCRETE
0MWM
135.8MGOMAG COAT 25% START
579MGOMAG COAT 70% START
143.6SAVSEVERE AGG
2MGOMAG COAT 70% START 8:00 TO 4:00
692.4SSS
154.2SRVLONG REBAR

Properties (4)

custom_field_three
LONG & CIRCUM REBAR VISIBLE SPORATIC
custom_field_two
2
customer
LACSD
datetime
2016-02-23T00:44:32-08:00