- Date
- 02/22/2016
- W/O
- 0541683
- Weather
- Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00316
- PipeID
- P07852
- Time
- 10:05 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7057
- Sewer Name
- A JOA-1A DISTRICT 21 INTERCEPTOR
- City
- INDUSTRY
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 34
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160222AM_JOA_1A_DISTRICT_21_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Upstream MH
- A 0645
- Downstream MH
- A 0644
- Dir. of Survey
- Downstream
- Length Surveyed
- 950.1 ft.
- Total Length
- 950.1 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole A 0645 to A 0644 Observation photos (3)

2 ft. - General Observation - 90% MAG COAT INTACT FROM 09 TO 03 O'CLOCK, START

933.6 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - ACTIVE

948.5 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO