30 0224_30 0270_2192016_103011.mp4
0 ft. - Upstream Manhole, Survey Begins - 10.28 AM
2 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: NO, Start
2 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start
2.7 ft. - General Photograph - BROKEN PIPE
3.1 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES
4 ft. - General Photograph - BROKEN PIPE
4 ft. - Broken Soil Visible, from 11 to 01 o'clock, within 8 inches of joint: YES
4 ft. - General Observation - CHIPPING ALL AROUND THE JOINT
4 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES
4 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
13.4 ft. - General Observation - CORRODED CHANNEL
| Distance | Code | Observation |
|---|---|---|
| 4 | MGP | BROKEN PIPE |
| 13.3 | MGO | SLIGHT GREASE THROUGHOUT THE REACH |
| 13.4 | MGO | CORRODED CHANNEL |
| 2 | SSS | — |
| 0 | MWL | — |
| 0 | MGO | ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK |
| 4 | BSV | — |
| 13.5 | AMH | 10:49 AM |
| 13.3 | SSS | — |
| 4 | MGO | CHIPPING ALL AROUND THE JOINT |
| 3.1 | B | — |
| 2 | SAV | — |
| 4 | B | — |
| 13.3 | SAV | — |
| 2.7 | MGP | BROKEN PIPE |
| 4 | FM | — |
| 0 | MWM | — |
| 0 | AMH | 10.28 AM |
| 10.6 | FM | — |