Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2016, 11:37 AM
  • A 0307_A 0306_2112016_035739.mp4

Date
02/11/2016
W/O
0556813
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00325
PipeID
P08217
Time
3:37 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0050
Sewer Name
A JOA-1A SAN JOSE CREEK WRP INTERCEPTOR
City
EL MONTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
20160211MDM_JOA_1A_SAN_JOSE_CREEK_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
63 in.
Upstream MH
A 0306
Downstream MH
A 0307
Dir. of Survey
Upstream
Length Surveyed
6.5 ft.
Total Length
6.5 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole A 0306 to A 0307
MH: A 0306MH: A 0307upstream0 ft. MSA - Survey Abandoned - UPLEG DOWNSTREAM SIPHON0.5 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG0.5 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish2.5 ft. MGO - General Observation - SEALED JOINTS4.5 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE EXPOSED AGG4.5 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING LAITANCE COAT6.5 ft. MWM - Water Mark, 80 %of cross sectional area6.5 ft. AMH - Downstream Manhole, Survey Begins - 3:35AM6.5 ft. MWL - Water Level, 50 %of cross sectional area

Observation photos (5)

  • Water Mark, 80 %of cross sectional area

    0 ft. - Water Mark, 80 %of cross sectional area

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE EXPOSED AGG

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE EXPOSED AGG

  • Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING LAITANCE COAT

    2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - PEELING BLISTERING LAITANCE COAT

  • General Observation - SEALED JOINTS

    4 ft. - General Observation - SEALED JOINTS

  • Survey Abandoned - UPLEG DOWNSTREAM SIPHON

    6.5 ft. - Survey Abandoned - UPLEG DOWNSTREAM SIPHON

Observations (9)

DistanceCodeObservation
2SAVSEVERE EXPOSED AGG
6.5MSAUPLEG DOWNSTREAM SIPHON
0MWM
0AMH3:35AM
2SSSPEELING BLISTERING LAITANCE COAT
0MWL
6SAVSEVERE AGG
4MGOSEALED JOINTS
6SSS

Properties (5)

additional_info
UPLEG DOWNSTREAM SIPHON
custom_field_three
SEVERE AGG VISIBLE
custom_field_two
3
customer
LACSD
datetime
2016-02-11T03:37:54-08:00