- Date
- 02/10/2016
- W/O
- 0541683
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00316
- PipeID
- P07919
- Time
- 12:53 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- HOO48
- Sewer Name
- A JOA-1A DISTRICT 21 INTERCEPTOR
- City
- POMONA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160210MDM_J0A_1A_DISTRICT_21_INTERCEPTOR
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Upstream MH
- A 0710
- Downstream MH
- A 0709
- Dir. of Survey
- Downstream
- Length Surveyed
- 23.8 ft.
- Total Length
- 23.8 ft.
- Structural Index
- 5
- Structural Quick
- 5241
- Structural Rating
- 14
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole A 0710 to A 0709 Observation photos (5)

2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

2 ft. - General Observation - MAG COAT 70% 10:00 TO 2:00 START

2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR UNDER MAG COAT

14.1 ft. - General Photograph - CORRODED REBAR

14.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR