Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2016, 12:25 PM
  • 05 2204_05 2203_232016_051621.mp4

Date
02/03/2016
W/O
0536424
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00509
PipeID
P07351
Time
4:25 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0041
Sewer Name
05 PRAIRIE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
20160201MDM_PRAIRIE_AVENUE_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 2204
Downstream MH
05 2203
Dir. of Survey
Downstream
Length Surveyed
320.8 ft.
Total Length
320.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
4432
O&M Rating
22
Overall Index
4
Overall Quick
Overall Rating
22
Pipe schematic from manhole 05 2204 to 05 2203
MH: 05 2204MH: 05 2203downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 5:10AM2 ft. MGP - General Photograph - VCP2 ft. MMC - Material Change, Vitrified clay pipe - START2 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start45 ft. MGP - General Photograph45 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES166 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start166 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish220 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish220 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start223 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish233 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start274 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES320.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active320.1 ft. DAGS - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish320.1 ft. MMC - Material Change, Vitrified clay pipe - FINISH320.8 ft. AMH - Downstream Manhole, Survey Ends - 5:40AM

Observation photos (9)

  • General Photograph - VCP

    2 ft. - General Photograph - VCP

  • Material Change, Vitrified clay pipe - START

    2 ft. - Material Change, Vitrified clay pipe - START

  • Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Photograph

    45 ft. - General Photograph

  • Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    45 ft. - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    166 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    220 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    233 ft. - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES

    274 ft. - Deposits Attached Grease, 25 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
2MGPVCP
233DAGS
320.1MGOConn. @ Mh, 9 O' Clock. Active
45MGP
166DAGS
0MWM
220DAGS
220DAGS
320.8AMH5:40AM
2MMCSTART
320.1DAGS
0MWL
223DAGS
2DAGS
320.1MMCFINISH
274DAGS
166DAGS
0AMH5:10AM
45DAGS

Properties (3)

custom_field_two
24" VCP
customer
LACSD
datetime
2016-02-03T04:25:53-08:00