Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2016, 09:47 AM
  • 15 0053_15 0052_1272016_021452.mp4

Date
01/27/2016
W/O
0554144
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00622
PipeID
P11946
Time
1:47 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0032
Sewer Name
15 PUENTE TRUNK
City
LA PUENTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Maintenance Related
Project
20160127MDM_PUENTE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
15 0053
Downstream MH
15 0052
Dir. of Survey
Downstream
Length Surveyed
279.5 ft.
Total Length
279.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 15 0053 to 15 0052
MH: 15 0053MH: 15 0052downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MGO - General Observation - MH CONN ACTIVE 9:000 ft. MWL - Water Level, 5 %of cross sectional area23.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open25.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"49.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"75.6 ft. MGP - General Photograph - 10" VCP76.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"99.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"126.6 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - SEVERE CRACK 6:00150.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"176.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"201 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN SEVERE OFFSET228 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 5" - Open251.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"258.8 ft. DAZ - Deposits Attached Other, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES - SCALE AND GREASE THROUGHOUT REACH275.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"279.5 ft. AMH - Downstream Manhole, Survey Ends - 2:55AM

Observation photos (5)

  • General Photograph - 10" VCP

    75.6 ft. - General Photograph - 10" VCP

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - SEVERE CRACK 6:00

    126.6 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - SEVERE CRACK 6:00

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN SEVERE OFFSET

    201 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN SEVERE OFFSET

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 5" - Open

    228 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 5" - Open

  • Deposits Attached Other, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES - SCALE AND GREASE THROUGHOUT REACH

    258.8 ft. - Deposits Attached Other, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES - SCALE AND GREASE THROUGHOUT REACH

Observations (19)

DistanceCodeObservation
201TFDOPEN SEVERE OFFSET
25.5TFC
228TFOpen
275.3TFC
279.5AMH2:55AM
126.6TFDSEVERE CRACK 6:00
0MWM
0AMH2:15AM
0MGOMH CONN ACTIVE 9:00
150.3TFC
75.6MGP10" VCP
76.1TFC
176.8TFC
258.8DAZSCALE AND GREASE THROUGHOUT REACH
251.5TFC
49.3TFC
23.1TBOpen
99.6TFC
0MWL

Properties (2)

customer
LACSD
datetime
2016-01-27T01:47:48-08:00