03 0264_03 0263A_1182016_114720.mp4
5.1 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES
35.3 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
71.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES
105 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
135.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES
168.1 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
187.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
232.2 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 2" - ACTIVE
287.3 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
343.4 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN, CRACKED, PROTRUDING IN APPROX. 2"
345.8 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
| Distance | Code | Observation |
|---|---|---|
| 348 | MGO | SLIGHT GREASE/DEBRIS THROUGHOUT THE REACH |
| 250.9 | CM | — |
| 348.4 | MGO | ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK |
| 105 | TFI | ACTIVE |
| 227.7 | CM | — |
| 314.4 | CL | — |
| 242.6 | CL | — |
| 135.3 | FL | — |
| 232.2 | TFI | ACTIVE |
| 279.2 | CM | — |
| 0 | MWL | — |
| 35.3 | TFI | ACTIVE |
| 345.8 | FL | POSSIBLY BROKEN |
| 0 | MWM | — |
| 343.4 | TFD | OPEN, CRACKED, PROTRUDING IN APPROX. 2" |
| 302.4 | CM | — |
| 287.3 | TFI | ACTIVE |
| 51 | CM | — |
| 74.6 | CM | — |
| 168.1 | TFI | ACTIVE |
| 71.6 | FL | — |
| 5.1 | FM | — |
| 0 | AMH | 11:45 AM |
| 347.8 | MGO | MULTIPLE CRACKS THROUGHOUT THE REACH |
| 266.6 | CM | — |
| 350.4 | AMH | 12:17 PM |
| 348.4 | MGO | ROACHES INSIDE THE MH. |
| 187.3 | CL | — |
| 223.4 | CM | — |
| 0 | MGO | ROACHES INSIDE THE MH. |