03 0265_03 0264_1182016_103250.mp4
34.6 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
99 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
230.8 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
295.3 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1", 6" - OPEN
358.9 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE
384.4 ft. - General Observation - CHIPPING @ THE JOINT
| Distance | Code | Observation |
|---|---|---|
| 6.1 | CL | — |
| 39.9 | CM | — |
| 389.7 | MGO | SLIGHT GREASE/DEBRIS THROUGHOUT THE REACH |
| 390 | MGO | ROACHES INSIDE THE MH. |
| 88.3 | CM | — |
| 0 | AMH | 10:32 AM |
| 295.3 | TFI | OPEN |
| 384.4 | MGO | CHIPPING @ THE JOINT |
| 358.9 | TFI | ACTIVE |
| 103.5 | CL | — |
| 0 | MGO | ROACHES INSIDE THE MH. |
| 230.8 | TFI | ACTIVE |
| 0 | MWM | — |
| 0 | MWL | — |
| 391.6 | AMH | 11:01 AM |
| 99 | TFI | ACTIVE |
| 162.9 | TFA | PROTRUDING IN LESS THAN AN INCH |
| 34.6 | TFI | ACTIVE |