Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 4, 2016, 09:44 AM
Date
01/04/2016
W/O
0546885
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00158
PipeID
P23007
Time
1:44 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6667
Sewer Name
D JOINT OUTFALL D - UNIT 7
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Capital Improvement Program Assesment
Project
20160104MDM_JOINT_OUTFALL_D_UNIY_7
Material
RCP-CTL
Shape
Circular
Height
60 in.
Upstream MH
D 0124
Downstream MH
D JOINT
Dir. of Survey
Downstream
Length Surveyed
721.7 ft.
Total Length
721.7 ft.
Structural Index
5
Structural Quick
5y4\
Structural Rating
2035
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
2035
Pipe schematic from manhole D 0124 to D JOINT
MH: D 0124MH: D JOINTdownstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:55AM0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAG COAT 70% START2 ft. MGO - General Observation - MISSING TILES 100% 8:00 TO 4:00 START2 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MISSING REBAR CORRODED BEYOUND REBAR2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG11 ft. MGP - General Photograph25.3 ft. SRC - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - MISSING REBAR50.4 ft. MGO - General Observation - MAG COAT 70%68.2 ft. SRP - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM98 ft. SRP - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES116.2 ft. MGO - General Observation - MISSING TILES 10%162.8 ft. MGP - General Photograph182.3 ft. MGO - General Observation - MAG COAT 70%229.6 ft. SRP - Surface Reinforcement Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES262.9 ft. MGO - General Observation - MAG COAT 60% START342.2 ft. MGO - General Observation - MISSING TILES 40%353.6 ft. MGO - General Observation - MISSING TILES 60%374.5 ft. MGO - General Observation - MISSING TILES 20%486 ft. MGO - General Observation - MAG COAT40%495.3 ft. MGO - General Observation - MISSING TILES 20%564 ft. MGP - General Photograph - CORRODED BEYOUND REBAR625.7 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES632.2 ft. MGP - General Photograph651.3 ft. MGP - General Photograph680 ft. MGP - General Photograph703.9 ft. MGP - General Photograph721.1 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish721.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - MISSING REBAR - CORRODEDE BEYOUND REBAR721.1 ft. MGO - General Observation - MAG COAT 40% FINISH721.1 ft. MGO - General Observation - MH CONN ACTIVE 9:00721.1 ft. MGO - General Observation - MISSING TILES FINISH721.1 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish721.7 ft. AMH - Downstream Manhole, Survey Ends - 4:40AM

Observation photos (25)

  • General Observation - MAG COAT 70% START

    2 ft. - General Observation - MAG COAT 70% START

  • General Observation - MISSING TILES 100% 8:00 TO 4:00 START

    2 ft. - General Observation - MISSING TILES 100% 8:00 TO 4:00 START

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MISSING REBAR CORRODED BEYOUND REBAR

    2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - MISSING REBAR CORRODED BEYOUND REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • General Photograph

    11 ft. - General Photograph

  • Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - MISSING REBAR

    25.3 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - MISSING REBAR

  • General Observation - MAG COAT 70%

    50.4 ft. - General Observation - MAG COAT 70%

  • Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

    68.2 ft. - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM

  • Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

    98 ft. - Surface Reinforcement Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

  • General Observation - MISSING TILES 10%

    116.2 ft. - General Observation - MISSING TILES 10%

  • General Photograph

    162.8 ft. - General Photograph

  • General Observation - MAG COAT 70%

    182.3 ft. - General Observation - MAG COAT 70%

  • Surface Reinforcement Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    229.6 ft. - Surface Reinforcement Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - MAG COAT 60% START

    262.9 ft. - General Observation - MAG COAT 60% START

  • General Observation - MISSING TILES 40%

    342.2 ft. - General Observation - MISSING TILES 40%

  • General Observation - MISSING TILES 60%

    353.6 ft. - General Observation - MISSING TILES 60%

  • General Observation - MISSING TILES 20%

    374.5 ft. - General Observation - MISSING TILES 20%

  • General Observation - MAG COAT40%

    486 ft. - General Observation - MAG COAT40%

  • General Observation - MISSING TILES 20%

    495.3 ft. - General Observation - MISSING TILES 20%

  • General Photograph - CORRODED BEYOUND REBAR

    564 ft. - General Photograph - CORRODED BEYOUND REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES

    625.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES

  • General Photograph

    632.2 ft. - General Photograph

  • General Photograph

    651.3 ft. - General Photograph

  • General Photograph

    680 ft. - General Photograph

  • General Photograph

    703.9 ft. - General Photograph

Observations (36)

DistanceCodeObservation
342.2MGOMISSING TILES 40%
353.6MGOMISSING TILES 60%
68.2SRPCIRCUM
721.1SAM
625.7SRC
721.1SRCMISSING REBAR - CORRODEDE BEYOUND REBAR
2MGOMAG COAT 70% START
721.1MGOMAG COAT 40% FINISH
721.1MGOMH CONN ACTIVE 9:00
721.1MGOMISSING TILES FINISH
703.9MGP
229.6SRP
0MWM
564MGPCORRODED BEYOUND REBAR
2MGOMISSING TILES 100% 8:00 TO 4:00 START
486MGOMAG COAT40%
2SRCMISSING REBAR CORRODED BEYOUND REBAR
116.2MGOMISSING TILES 10%
721.1SRC
2SRCLONG & CIRCUM REBAR
374.5MGOMISSING TILES 20%
162.8MGP
721.7AMH4:40AM
680MGP
0AMH3:55AM
182.3MGOMAG COAT 70%
495.3MGOMISSING TILES 20%
262.9MGOMAG COAT 60% START
0MWL
25.3SRCMISSING REBAR
98SRP
50.4MGOMAG COAT 70%
651.3MGP
2SAMSEVERE AGG
11MGP
632.2MGP

Properties (4)

custom_field_three
MISSING REBAR - CORRODED BEYOUND REBAR
custom_field_two
1
customer
LACSD
datetime
2016-01-04T01:44:11-08:00