Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 17, 2015, 06:28 PM
  • 18 1227_18 1226_12172015_113258.mp4

Date
12/17/2015
W/O
0541713
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z01143
PipeID
P25607
Time
10:28 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7019
Sewer Name
18 WORSHAM CREEK REPLACEMENT TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Routine Assessment
Project
20151217SHO_WORSHAM_CREEK_REPLACEMENT_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 1227
Downstream MH
18 1226
Dir. of Survey
Downstream
Length Surveyed
377.7 ft.
Total Length
377.7 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 1227 to 18 1226
MH: 18 1227MH: 18 1226downstream0 ft. AMH - Upstream Manhole, Survey Begins - 11300 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area27.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open75.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"117.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open141.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open143.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open151.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"152 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open201.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open203.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"232.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open234 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open265.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open271.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"281.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open286.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active296.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"320.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open330 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"360.9 ft. SSS - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: YES367.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open374 ft. MGO - General Observation - Grease Throughout The Reach (5%)377.7 ft. AMH - Downstream Manhole, Survey Ends - 1155

Observations (26)

DistanceCodeObservation
151.1TFC
374MGOGrease Throughout The Reach (5%)
203.1TFC
0AMH1130
286.9TFAActive
281.3TFOpen
232.4TFOpen
377.7AMH1155
234TFOpen
271.5TFC
117.3TFOpen
296.9TFA
27.4TFOpen
330TFA
0MGOConn. @ Mh, 3 O' Clock. Active
75.1TFA
143.7TFOpen
360.9SSS
0MWL
0MWM
201.5TFOpen
152TFOpen
141.1TFOpen
320.9TFOpen
265.6TFOpen
367.7TFOpen

Properties (4)

custom_field_three
ONE SMALL SPOT OF SPALLING
custom_field_two
3
customer
LACSD
datetime
2015-12-17T10:28:32-08:00