- Date
- 12/15/2015
- W/O
- 0538789
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00784
- PipeID
- P16118
- Time
- 1:29 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0003
- Sewer Name
- 21 SAN ANTONIO TRUNK
- City
- CLAREMONT
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 06
- Purpose
- Capital Improvement Program Assesment
- Project
- 20151215MDM_SAN_ANTONIO_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 21 1018
- Downstream MH
- 21 1017
- Dir. of Survey
- Downstream
- Length Surveyed
- 321.8 ft.
- Total Length
- 321.8 ft.
- Structural Index
- 3
- Structural Quick
- 4133
- Structural Rating
- 23
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 31
Pipe schematic from manhole 21 1018 to 21 1017 Observation photos (9)

66.4 ft. - General Observation - DROP IN GRADE

279.6 ft. - General Photograph

279.6 ft. - Repair Patch Defective, from 08 to 02 o'clock, within 8 inches of joint: YES - REPAIR AREA CORRODING

279.6 ft. - General Photograph - REPAIR AREA

279.6 ft. - General Observation - REPAIR MATERIAL IN FLOW

279.6 ft. - General Photograph

279.6 ft. - General Photograph

282.9 ft. - Repair Patch, from 11 to 01 o'clock, within 8 inches of joint: YES - IN PLACE

321.6 ft. - General Observation - MH LARGE AMOUNT ROOTS